At 10,000 samples per second, a measurement accuracy of ±0.01 % and 24 bit resolution, Beckhoff’s EtherCAT Terminal EL3751 with eXtreme Fast Control technology (XFC) provides high-end measurement technology as part of the standard I/O system.
High-precision acquisition of measurement data offers potential to optimize machine efficiency and production quality. This can also be achieved for demanding measurement technology tasks with the system-integrated EL3751 solution from Beckhoff, which combines automation and measurement technology on one universal hardware and software platform.
The "Extended Range" feature in the EL3751 enables measurement beyond the nominal measuring range, with possible extension up to 107 percent. To suppress aliasing effects, the input channel features two configurable numeric software filters up to 39th order FIR / 6th order IIR. The filters can be preselected or freely defined, so that a band stop or a band pass can be implemented.